Are you Ken Gall? Register this Author. 52Publications. 326Reads. 32Profile Views. Fatigue behavior of As-built selective laser melted titanium scaffolds with sheet-based gyroid microarchitecture for bone tissue engineering. Authors: Cambre N Kelly Jaedyn Francovich S Julmi David Safranski Robert E Guldberg Hans J Maier Ken Gall.

Jack Griffis - Senior Vice President, Advanced ....

Se Jack Griffis profil på LinkedIn, världens största yrkesnätverk. Jack har angett 6 jobb i sin profil. Se hela profilen på LinkedIn, upptäck Jacks kontakter och hitta jobb på liknande företag.

Bearing Area: A New Indication for Suture Anchor Pullout ....

Bearing Area: A New Indication for Suture Anchor Pullout Strength? Christopher Michael Yakacki,1,2 Jack Griffis,1 Mariya Poukalova,3 Ken Gall1,2,4 1Research and Development, MedShape Solutions, Atlanta, Georgia 30318, 2School of Materials Science and Engineering, The Georgia Institute of Technology, Atlanta, Georgia 30332, 3Wallace H. Coulter Department of Biomedical Engineering, The Georgia ...

Pullout Strength of Suture Anchors: Effect of Mechanical ....

Yakacki CM, Griffis J, et al. Bearing area: A new indication for suture anchor pullout strength? Journal of Orthopaedic Research. 2009; 27 (8):1048–1054. Yakacki CM, Poukalova M, et al. Pullout Strength of Suture Anchors - Part I: Effect of Trabecular Microstructure using Micro-CT. (In Review)

All-Suture Anchors: Biomechanical Analysis of Pullout ....

All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode ... out of the bone. 3 This is not to minimize the fact that even a loose suture in the joint can be destructive. 7 With an all-suture based anchor, anchor pullout can result in a suture-ball within the joint, which can cause unappreciated damage ...

Jack Griffis - Senior Vice President, Advanced ....

The bearing area of a suture anchor can be used to predict the pullout strength independent of design in a soft-bone model. Other authors Influence of design on pull-out of suture anchors in a low ...

Marie Buharin - Director, Regulatory Affairs - Fractyl ....

Bearing Area: A new Indication for Suture Anchor Pullout Strength? Journal of Orthopedic Research January 1, 2009 The bearing area of a suture anchor can be used to predict the pullout strength ...

The Effect of the Trabecular Microstructure on the Pullout ....

Sher et al. 1995) Poor bone and tissue quality are the main factors of anchor-bone and suture-tendon pullout, respectively, and research has been focused on the use of suture anchors in the aging population.(Rebuzzi et al. 2005) Several researchers have attempted to link the properties of bone to suture anchor pullout strength.

Publications Authored by Jack Griffis | PubFac...

Bearing area: a new indication for suture anchor pullout strength? Authors: Christopher Michael Yakacki Jack Griffis Mariya Poukalova Ken Gall. J Orthop Res 2009 Aug;27(8):1048-54. Research and Development, MedShape Solutions, Atlanta, Georgia 30318, USA. View Article. Download full-text PDF

The Effect of the Trabecular Microstructure on the Pullout ....

The Effect of the Trabecular Microstructure on the Pullout Strength of Suture Anchors. ... Other researchers have been able to predict the pullout strength of anchors in synthetic bone by using both shear and bearing area ... Bearing area: A new indication for suture anchor pullout strength? (In Press), n/a. Formats: Article ...

Pullout strength of suture anchors: Effect of mechanical ....

Pullout strength of suture anchors: Effect of mechanical properties of trabecular bone. ... and suture anchor pullout strength. Twelve fresh-frozen humeri underwent mechanical testing followed by micro-computed tomography (μCT). ... C.M. Yakacki, J. Griffis, et al.Bearing area: a new indication for suture anchor pullout strength? Journal of ...

Makale » DergiPa...

Bearing area: A new indication for suture anchor pullout strength?. Journal of Ortopaedic Research. (27/8), 1048-1054. [54] Elahinia ME, Hashemi M, tabesh M. 2012. Manufacturing and processing of NiTi implants: A review , progress in Materials Science, (57), 911-946.[55]

All-Suture Anchors: Biomechanical Analysis of Pullout ....

All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode ... out of the bone. 3 This is not to minimize the fact that even a loose suture in the joint can be destructive. 7 With an all-suture based anchor, anchor pullout can result in a suture-ball within the joint, which can cause unappreciated damage ...

Minimum Distance of Suture Anchors Used for Rotator Cuff ....

The contact area of the anchor thread is known to be strongly correlated to the pullout strength.27, 32 With 2 anchors inserted at the distance of 4 mm, the anchor threads overlapped 1.3 mm with the metal anchors and 0.3 mm with the PEEK anchors, resulting in decrease in the contact area between the threads and bone.

The Design and Pullout Strength of a Novel Shape-Memory ....

A shape-memory PEEK suture anchor can be created and mechanically activated with the potential for repairs in vivo. The 3.5 and 5.5 mm sized winged design exhibited average pullout strengths of 295 and 566 N. References 1. Yakacki CM, Griffis J, Poukalova M, Gall K. Bearing area: A new indication for suture anchor pullout strength?

Pullout strength of knotless suture anchors | Request P...

The purpose of this study was to analyze the pullout strength of a new knotless suture anchor (Mitek Knotless Suture Anchor; Mitek, Norwood, MA) compared with 2 commercially available suture ...

Bone Anchors—A Preliminary Finite Element Study of Some Factors Affecting Pullo...

One of the key outcomes from the model is that the coefficient of friction between bone and anchor determines potential mechanisms of pullout. The stiffness of anchors and the effect of the cortical layer are presented for different pullout angles to obtain the theoretical response.

The Characteristics of Two Sizes of the JuggerKnot Mini 1 ....

Background: This study was to investigate the characteristics and the basic data of two sizes of the JuggerKnot Mini 1.0 mm. Methods: Twenty-three 3-0 and thirty-four 2-0 anchors were inserted into synthetic bone, and we used twenty 3-0 and 2-0 anchors each which had been inserted correctly on the first attempt.

- Shape-Memory Polymer Device Design. A volume in Plastics ....

[21] Yakacki CM, et al. Bearing area: a new indication for suture anchor pullout strength? J Orthopaed Res 2009;27(8):1048—54. [22] Smith KE, et al. Anterior cruciate ligament fixation: is radial force a predictor of the pullout strength of soft-tissue interference devices?. Knee 2012;19(6):786—92.

Bearing area: a new indication for suture anchor pullout ....

The bearing area of a suture anchor can be used to predict the pullout strength independent of design in a soft-bone model. This work helps provide a foundation to understand the principles that affect the pullout strength of suture anchors.

Bone Anchors—A Preliminary Finite Element Study of Some ....

One of the key outcomes from the model is that the coefficient of friction between bone and anchor determines potential mechanisms of pullout. The stiffness of anchors and the effect of the cortical layer are presented for different pullout angles to obtain the theoretical response.